(Select the best-fit configuration by combining output options (5 A / 1 A / 100 mA / 333 mV / 1 V) with accuracy classes (IEC 0.5 / 1 / 3.0 or IEEE 0.6 / 1.2) within the lineup.)
Revenue-Grade Split Core CTs
– UL2808, 225mV·333mV·1V·100mA·1A·5A
1. Description
UL 2808–certified revenue-grade split core current transformer (split-core CT) for fast, tool-friendly retrofit on primary conductors. Offers 225 mV/333 mV/1 V and 100 mA/1 A/5 A outputs, with built-in safety features for energy monitoring and billing.
2. Key Features
- UL 2808 certified revenue-grade split core CT for field-installed metering and submetering
- Split-core (clamp-on) design: mounts quickly on primary conductors without cutting or disconnecting wiring—ideal for retrofits
- No shorting block required thanks to output-type safety design
- Voltage outputs (225 mV / 333 mV / 1 V): low-voltage options matched to meter inputs (333 mV includes built-in burden resistor)
- Current outputs (1 A / 5 A): built-in overvoltage protection enables safe operation without a shorting block
- One-hand installation even with gloves for improved onsite safety and productivity
- Ultra-low phase angle error essential for accurate power and energy measurement
3. Accuracy & Standards Positioning
- IEC 61869-2 accuracy class: 0.2S / 0.5S
- IEEE C57.13 accuracy class: 0.15 / 0.3 / 0.3S
4. Output Options
| Item | Options |
|---|---|
| Voltage Output | 225 mV, 333 mV (0.333 Vac), 1 V |
| Current Output | 100 mA, 1 A, 5 A |
| Selection Guidance | Choose by meter input type (voltage/current) and required accuracy |
5. Series
| Model (Series) |
Available Outputs |
|---|---|
| JPS | 333 mV, 100 mA |
| QACT | 333 mV, 100 mA |
| JSC | 225 mV, 333 mV, 1 V, 100 mA, 1 A, 5 A (configurable options) |
High-Precision PQ Split Core CTs
– IEC 61557-12(PMD), PMD-III Advanced Power Monitoring
1. Description
High-precision power quality split-core CTs are designed for IEC 61557-12 (PMD)–based PMD-III advanced power monitoring and network performance analysis. Including revenue-grade split-core CTs (JPS/QACT/JSC), they support harmonic and load-variation monitoring with IEC 61869-2 0.2S/0.5S and IEEE C57.13 0.15/0.3/0.3S options.
2. Key Features
- Power quality (PQ) CT lineup for IEC 61557-12 (PMD): ideal for PMD-III advanced power monitoring and network performance assessment
- Standards-based accuracy class options
- IEC 61869-2: 0.2S / 0.5S
- IEEE C57.13: 0.15 / 0.3 / 0.3S - PQ lineup including revenue-grade split-core CTs (JPS / QACT / JSC): expands PQ measurement coverage while maintaining field-install convenience and meter compatibility
- High-permeability PC80 permalloy core: improved waveform fidelity in distortion, harmonics, and high-frequency conditions
- Supports inverter environments up to 20 kHz: optimized for variable frequency drives (VFDs), inverters, and high-switching power electronics
- Split-core design minimizes downtime: clamp-on installation without cutting cables reduces installation time and onsite risk
3. Accuracy & Standards
| Standard | Supported Accuracy Classes | Scope / Positioning |
|---|---|---|
| IEC 61557-12 (PMD) | PMD-III context | Designed for PMD-III advanced power monitoring and network performance measurement applications |
| IEC 61869-2 | 0.2S / 0.5S | Compliance-ready for high-accuracy current transformer (CT) measurement in power monitoring systems |
| IEEE C57.13 | 0.15 / 0.3 / 0.3S | Supports industry-standard CT accuracy classes for precise energy and power quality measurement |
4. Series
| Model (Series) |
Overview | Typical Applications |
|---|---|---|
| JPS / QACT / JSC / JM21 | Power quality split-core CT lineup built on revenue-grade split-core CT platforms, including configurations for power quality measurement | PMD-III monitoring, harmonic analysis, load variation tracking, inverter/VFD environments up to 20 kHz |
General Metering Split Core CTs
– PMD-I / PMD-II, IEC 61557-12
1. Description
General-purpose split-core CTs are ideal for IEC 61557-12 PMD-I (energy efficiency) and PMD-II (basic power monitoring) applications. Optimized for power meters and multi-channel meters to monitor primary conductors and branch circuits, with 5 A/1 A/100 mA/333 mV/1 V outputs for fast, cost-effective energy monitoring.
2. Key Benefits
- Split-core CT design enables fast clamp-on installation without cutting cables, minimizing retrofit downtime
- Ideal for branch circuit monitoring, allowing per-circuit load tracking with power meters and multi-channel meters
- Built for IEC 61557-12 (PMD) environments, optimized for PMD-I (energy efficiency) and PMD-II (basic power monitoring) energy monitoring
- Wide range of standard secondary outputs (5 A / 1 A / 100 mA / 333 mV / 1 V) for broad meter compatibility and easy system integration
3. Applications
- PMD-I: Energy efficiency monitoring (IEC 61557-12 PMD)
- PMD-II: Basic power monitoring for facility energy visibility
- Seamless integration with power meters and multi-channel meters (meter input compatible)
- Ideal for branch circuit and equipment load monitoring, optimized for retrofit (clamp-on) installation
4. Accuracy Classes
- IEC 61869-2 accuracy classes: 0.5 / 1 / 3.0
- IEEE C57.13 accuracy classes: 0.6 / 1.2
5. Output Options
| Output Type | Options | - |
|---|---|---|
| Current Output | 5 A / 1 A / 100 mA | Standard secondary current outputs for broad meter compatibility |
| Voltage Output | 333 mV (0.333 Vac) / 1 V | Low-voltage outputs commonly used in energy monitoring and submetering |
| Selection Guidance | Select by meter input type (current/voltage) and installation conditions | Improves compatibility for IEC 61557-12 PMD energy monitoring systems |
6. Series
| Model (Series) |
Positioning |
|---|---|
| JC | General-purpose split-core current transformer (CT) for PMD-I/PMD-II monitoring |
| JS | Clamp-on CT series for power meter / multi-channel meter integration |
| JSC | Flexible split-core CT lineup supporting multiple outputs and accuracy needs |
| JM21 | Retrofit-friendly split-core CT series for branch circuit and facility monitoring |